iv infusion pump
Features:
1. Compatible with IV sets of any brand, universal type.
2. Automatically calibration for IV sets of any brand.
3. Three working modes: Drop counting control, Rate control and Time control mode.
4. 6 Hours continuous work when the battery is fully charged.
5. Have a unique color LCD and an internal battery with a high capability.
6. Switch between ml/h and drops/min freely.
7. Three levels of alarm volume: high, medium and low.
8. Three levels of occlusion pressure: high, medium and low.
9. KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state.
Technical Specifications:
PARAMETER | SPECIFICATION |
Drop Detector | Outside caliper rotary detector (patent) Infrared sensor |
Control Way | Drop counting and adjusting the delivery rate automatically |
Fit IV tubes | 20d/ml,60d/ml and other, as well as brown tubes |
Pump Type | Peristaltic finger pump |
Accuracy | ±2%, when delivery rate ≤25drop/min (drop counting & time control mode) ±3%, when delivery rate >25drop/min (drop counting & time control mode) ±5% (Volume control mode after the correct calibration) |
Delivery rate | 1.0~1200ml/hr (1.0~99.9ml/h 0.1ml/h per step; 100~1200ml/h, 1.0ml/h ) |
Delivery time range | 1-1999min (1min step) |
Volume limit range: | 0-9999ml (1 ml step) |
Total Volume Range | 0-9999.9ml (1 ml step) |
Purge Rate | 600.0ml/h |
KVO Rate | KVO is 1ml/h when the delivery rate≤10ml/h, Otherwise KVO is 3ml/h. |
Occlusion pressure | Three level setting LOW, MEDIUM or HIGH |
Alarms | Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures. Three levels of alarm volume LOW, MEDIUM or HIGH |
Bolus function | Bolus rate:10-1200ml/h,Bolus volume: maximum of 100ml |
Power source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz;Built-in Lithium Battery: Rechargeable,11.1V,2000mAh. 6 hours of continuous operation |
Accessories: | AC power line, Operational manual |
Protection Class | Class I, Type CF,IPX4 |
Dimension /Net weight | 130mm*200mm*230mm , 2.5kg |